It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of such treatments for stainless steel parts. 1.2 Practices for the mechanical and chemical treatments of stainless steel surfaces are ...
the ASTM website. 3 Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. 4 In accordance with QQ-P-35C Notice 3, …
2.1 ASTM Standards:2 A380/A380M Practice for Cleaning, Descaling, and Passi-vation of Stainless Steel Parts, Equipment, and Systems A967/A967M Specification for Chemical Passivation Treat-ments for Stainless Steel Parts B117 Practice for Operating Salt Spray (Fog) Apparatus B322 Guide for Cleaning Metals Prior to Electroplating
ASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and …
ASTM A967/A967M-17 (CITRIC ACID) 7.1.1.1 Citric 1—The solution shall contain 4 to 10 weight percent of citric acid. The parts shall be immersed for a minimum of 4 min at a temperature in the range from 60 to 70°C [140 to 160°F] 7.1.1.2 Citric 2—The solution shall contain 4 to 10 weight percent of citric acid.
Normes remplacées (1) ASTM A967/A967M-13. février 2013. Norme Annulée. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning ...
ASTM A967-01 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts . 1. Scope(범위) * Stainless Steel 의 descaling, cleaning, passivation 에 대한 권고 및 예방책을 제시한다.
ASTM-A967, "Standardization Specification for Chemical Passivation Treatments for Stainless Steel Parts", was adopted on 31-MAR-97 for use by the Department of Defense (DoD). Proposed changes by DoD activities must be submitted to the DoD Adopting Activity: Defense Supply Center Richmond, Attn: DSCR-VFT/VEA, Richmond, VA 23297-5610.
Per ASTM A967 and A380, stainless parts are shown to be properly passivated if they resist corrosion in salt spray for just 2 hours. Stainless steel performs relatively poorly in salt spray because the constant exposure to a harsh environment rapidly erodes the passivation layer and prevents it from reforming.
6.1 Passivation Treatment:6.1.1 Stainless steel parts shall be treated in one of the. following aqueous solutions and maintained within the speci-fied temperature range for the specified time. 6.1.1.1 Nitric 1—The …
Stainless Steel Parts, Equipment and Systems. ASTM A967 Standard provides tests with acceptance criteria to demonstrate that the passivation procedures have been successful. As per ASTM International Standards; "passivation testing is the process by which stainless steel will spontaneously form a chemically inactive surface when exposed to ...
For example, ASTM A967 contains more options for passivation verification tests while AMS2700 provides more guidance on sampling large batches of components for testing and inspection after passivation. As the most direct linear descendant of QQ-P-35, AMS 2700 naturally shows its "heritage". QQ-P-35 types II, VI, VII and VIII are equivalent ...
メーカーにとって、astm a967 や ams 2700 などのは、ステンレスをするためにもにされるをしています。 astm a967 でべられているように、パッシベーションは、やそののをしながら、をむ ...
A citric acid passivation bath also takes far less time than nitric acid, speeding up the cleaning process considerably. However, for all these benefits, citric acid passivation is considerably more expensive, which is why many choose nitric acid to keep costs down. ASTM A967 details five different citric acid passivation methods: Citric 1: 4 ...
ASTM-A967, ADOPTION NOTICE: STANDARDIZATION SPECIFICATION FOR CHEMICAL PASSIVATION TREATMENTS FOR STAINLESS STEEL PARTS (31-MAR …
:ASTM A967/A967M タイトル:Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts ステンレスのパッシベーションの は、ステンレスのについてしたものである。をいた、クエンを ...
ASTM A967, 2005 Edition, September 1, 2005 - Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless …
Full Description. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for descaling, cleaning, and passivation of stainless steel parts. It includes several alternative tests, with acceptance criteria, for confirmation of effectiveness of ...
1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for …
A. ASTM A967 [affil link] is often specified for passivation of titanium, although it is a misnomer for sure. What you are removing by "passivation" of titanium is any iron or iron oxide that may have been put on the surface in the fabrication process of the parts. Even though you do not truly passivate the titanium metal itself, you need to ...
ASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. Language (s): English. Published date: 07-01-2017. Publisher: American Society for Testing and Materials.
Citric Acid Concentration: 4% ONLY in this phase. Immersion Times: 60, 90, and 120 minutes. Bath Temperatures: 38°C (100°F), 60°C (140°F), and 82°C (180°F) Salt Spray Testing per ASTM B 117. Corrosion Resistance Evaluation every 168 hours up to 504 hours of salt spray testing. Parameters resulting in the best corrosion resistance shall be ...
1. Passivation Process: ASTM A967 defines the passivation process as the removal of free iron or other foreign matter from the surface of stainless steel by means of a chemical treatment. This treatment encourages the formation of a passive oxide layer, strengthening the steel's resistance to corrosion. 2.
ASTM A967 Stainless Steel Passivation Standard: Nitric & Citric. Learn about the ASTM A967 specification that ensures nitric and citric stainless steel passivation is performed …
Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. ... ASTM Standard C33, 2003e1, "Specification for Concrete Aggregates," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/C0033 ...
ASTM B 117 salt spray testing for 2 to 3 hours, and then evaluated for signs of red rust. Red rust is considered a failure for passivation. In addition, the stainless steel test specimens were also examined for signs of IGA (intergranular attack) and pitting after being treated in the optimized nitric, optimized citric acid, and 3
Revision of A967/A967M-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Rationale. A967 was developed for replacement of Mil QQ-P 35. As part of the development, the word "dissolved" appears to be accidental dropped in para. 7.2. for the description of clean water. ... ASTM offers descriptions of …
Both AMS 2700 and ASTM A967 base their nitric acid passivation methods on using 42° Baume nitric acid. The Baume scale is a measurement of specific gravity. Positive degrees of Baume indicate chemicals or solutions denser than water. 42° Baume nitric acid corresponds to a 1.4 specific gravity solution of nitric acid that is roughly 67% …
Delstar is the industry leader in stainless steel passivation services, delivering the highest quality of passivated products to our customers since 2002. Here at Delstar Metal Finishing, we offer stainless steel passivation services with a focus on ASTM A967, ASTM A380, ASTM B912, and QQP35C specifications. Call or contact us today to speak to ...
The ASTM A967 passivation standard applies to the cleaning, passivation and testing of stainless steel parts. Chemical passivation removes free iron and other surface contaminants from stainless steel parts, improving corrosion resistance. Stainless steel passivation performed to the ASTM A967 standards meets these standards by passing …
Unpacking ASTM A967 – Industry Standard for Chemical Passivation Treatments ASTM A967/A967M – is a standard that details effective methods for …